An oil buffer that passed type approval at 1.0 m/s with a 1,000 kg gross load can still log a peak deceleration above 2.5 g once it is fitted to a 1.6 m/s machine in a real shaft. That gap between t...
READ MORE

The LSD03 elevator safety gear linkage mechanism utilizes a mechanical linkage design. When an elevator overspeeds or experiences an abnormality, the safety clamp is quickly activated, forcing the clamp block to engage the guide rails, reliably securing the car and ensuring the safety of passengers and equipment. This ingenious structural design provides multiple safety protections for the elevator system.
| Type of Safety Gear | Rated Speed (m/s) | Tripping Speed (m/s) | Rail Width (mm) | Permitted P+Q (kg) | Rail Lubrication | F | Certifications |
| LSG06 | 0.25 - 3.0 | 0.29 - 3.83 | 9 10 15.88 16 |
800 - 3300 | Oil | 130 140 150 160 170 180 |
GB/CE |
| 800 - 3300 | Dry | ||||||
An oil buffer that passed type approval at 1.0 m/s with a 1,000 kg gross load can still log a peak deceleration above 2.5 g once it is fitted to a 1.6 m/s machine in a real shaft. That gap between t...
READ MOREA lift car that exceeds its rated speed by 15 percent is already in a potentially dangerous condition. The elevator overspeed governor is the device specifically designed to detect that condition an...
READ MOREA 3,000 kg freight elevator overspeeds three floors above the pit, and the car has less than half a second before something must physically stop it. The first device to act is the overspeed governor...
READ MOREDuring a routine annual lift inspection, the test engineer drives the car at reduced speed and deliberately trips the overspeed governor. Whether the car stops safely depends on a component that is ...
READ MORE